Model directory

Model and frame-family records

Use an exact model or recognised frame family to locate connected fault, circuit and diagnostic records.

Danfoss VLT 2800 / VLT 2900
Danfoss VLT 2800 CB1-CB3 Control-Board Drawing Family

Compact-drive control board and keypad / I/O evidence family — The VLT 2800 CB1-CB3 control-board family is used for cases where the panel blinks, the display is incomplete, keypad replacement does not clear the symptom, a 10 V reference is loaded, or the low-voltage rails need to be separated from a downstream I/O or keypad load.

Open →
Danfoss VLT 2800 / VLT 2900
Danfoss VLT 2900 DB1-DB4 Power and Gate-Driver Drawing Family

Compact-drive power board, gate-driver and feedback evidence family — The VLT 2900 DB1-DB4 drawing family is used for compact Danfoss cases where Alarm 13, Alarm 14, Alarm 16 or repeat output-stage repair decisions need the DC link, auxiliary supply, gate-drive and current-feedback boundaries separated.

Open →
SIMOREG DC MASTER 6RA70
Siemens SIMOREG 6RA70 DC MASTER

Microprocessor-based DC thyristor converter — 6RA70 DC MASTER converters supply a DC motor armature and field from a three-phase AC supply. Service decisions usually need the fault value, parameter set, optimization-run state, selected feedback source, field architecture, armature circuit, CUD1 control electronics and power-interface / firing path to be separated.

Open →
SIMOREG DC MASTER 6RA70
Siemens SIMOREG 6RA70 DC MASTER

Microprocessor-based DC thyristor converter — 6RA70 DC MASTER converters supply a DC motor armature and field from a three-phase AC supply. Service decisions usually need the fault value, the selected operating state, the field architecture, the armature circuit, CUD1 control electronics and the power-interface / firing path to be separated.

Open →
DCS800
ABB DCS800 D1-D7 Converter Modules

Industrial DC drive converter platform — DCS800 D1-D7 modules require service routing by converter size and board chain. D1-D4 and D5-D7 do not use the same power-interface arrangement, and F521 FieldAck cannot be judged without knowing the field exciter and board architecture.

Open →
FRENIC5000 G9 / G11 Repair Platform
FRENIC5000 G9 / G11 repair family

Legacy Fuji FRENIC repair cluster for module and driver-fault decisions — Model-family page for technicians who inherited an older FRENIC5000 G9/G11 drive after one or more module replacements. It treats the drive as a repair evidence problem: module type, rectifier damage, driver leakage and safe bench setup come before another power module is purchased.

Open →
MICROMASTER 430 / 440 Service Track
MICROMASTER 430

Fan and pump variable frequency drive — MICROMASTER 430 is treated here as an installed fan/pump service platform: the important repair question is whether F0001, F0002 or F0003 is being produced by process inertia, ramp settings, motor/cable evidence, input supply, precharge/DC-link behaviour or an internal power-board boundary.

Open →
MICROMASTER 430 / 440 Service Track
MICROMASTER 440

General-purpose MICROMASTER 4 variable frequency drive — MICROMASTER 440 model coverage focuses on fault cases where the same F0001, F0002 or F0003 code may be caused by motor sizing, parameter mismatch, acceleration/deceleration limits, external 24 V / fieldbus behaviour, cable faults, supply/precharge faults or internal power-board evidence.

Open →
PowerFlex 520 / 750 Service Platform
Allen-Bradley PowerFlex 520 / 750 service platform

Rockwell Automation PowerFlex field-service reference — A practical service-platform record for PowerFlex drives where technicians need to decide whether a fault belongs to the motor/output path, input/DC bus, brake path, internal power stage, or HIM/DPI communication chain.

Open →
Unidrive SP / Unidrive M Service Platform
Control Techniques Unidrive SP / Unidrive M service platform

Control Techniques / Nidec high-performance drive service reference — A family-level diagnostic record for Unidrive SP and Unidrive M cases where the service question is usually a short trip label, a hoist/winder symptom, a feedback instability complaint or a failed control-supply condition.

Open →
Altivar ATV61 / ATV71
Altivar ATV61 / ATV71 service platform

Schneider Electric Altivar field-service reference — A practical family-level record for ATV61 and ATV71 drives, focused on the evidence a technician needs before classifying an OCF, SCF, OSF or USF trip as a supply, motor, cable, load, braking or drive-electronics problem.

Open →
VLT FC Service Platform
Danfoss VLT FC 102 / FC 202 / FC 302 service platform

Danfoss VLT FC-series field-service reference — A family-level diagnostic record for common VLT FC-series alarm cases, emphasizing phase-loss evidence, earth-fault isolation, output short-circuit checks, heatsink cooling evidence and overvoltage during deceleration.

Open →
ACS510 / ACS550
ACS510 / ACS550 standard drive platform

ABB standard AC drive field-service reference — A practical model-family record for ACS510 and ACS550 standard drives, oriented around nameplate identification, keypad evidence, external terminal wiring and the first diagnostic boundary for undervoltage, line-converter and overcurrent symptoms.

Open →
Cross-Brand VFD Fault Triage
Industrial VFD Power Stage

Three-phase rectifier, DC link and IGBT inverter stage — Generic power-stage record for industrial AC drives where incoming supply, rectifier, precharge, DC-link capacitors, braking circuit, gate driver and output bridge must be separated before condemning an IGBT module or control board.

Open →
Cross-Brand VFD Fault Triage
VFD Control Power Supply Stage

Auxiliary SMPS and logic-supply diagnostic boundary — Generic no-display and weak-display record for drives where the keypad, CPU, fan relay, gate-driver supply and feedback circuits depend on auxiliary low-voltage rails derived from the DC bus or an auxiliary input.

Open →
Cross-Brand VFD Fault Triage
VFD DC Link and Braking Stage

DC bus, braking chopper and regeneration-energy boundary — Generic DC-link record for overvoltage and deceleration faults where load inertia, ramp time, braking resistor selection, chopper hardware and input supply conditions must be separated.

Open →
Parker / Eurotherm 590P, 591P and 514C DC Drives
Eurotherm / Parker 590P Digital DC Drive Family

Digital DC thyristor converter family — 590P family record for digital DC drive diagnostics where OVER I TRIP, FIELD FAIL, missing-pulse and feedback-related problems require separation of motor, field, feedback electronics and firing hardware.

Open →
Parker / Eurotherm 590P, 591P and 514C DC Drives
Eurotherm / Parker 591P Regenerative DC Drive Drawing Family

Four-quadrant regenerative DC drive drawing reference — 591P drawing-family record using DB1 and DB2 references to organize auxiliary supply, armature current feedback, comparator and firing-path evidence for older regenerative DC converters.

Open →
Parker / Eurotherm 590P, 591P and 514C DC Drives
Eurotherm / Parker 514C Analog DC Controller Family

Analog DC motor controller / thyristor bridge controller — 514C drawing-family record for older analog DC controllers where no-output, field loss, thyristor bridge and firing evidence must be separated from external motor and supply conditions.

Open →
SJ300 / L300P Legacy Inverter Family
Hitachi SJ300 5.5 kW Drawing Family

Reviewed 5.5 kW board drawing set — SJ300-5.5KW DB1 through DB4 drawing-family record for control-supply, current-feedback and output-stage evidence. It is not universal compatibility proof.

Open →
SJ300 / L300P Legacy Inverter Family
Hitachi SJ300 7.5 kW Drawing Family

Reviewed 7.5 kW board drawing set — SJ300-7.5KW DB1 through DB4 record supporting E01-E04, E07, E09, no-display and repair/refurbishment decisions for matched 7.5 kW frames.

Open →
SJ300 / L300P Legacy Inverter Family
Hitachi SJ300 / L300P Repair and Replacement Context

Lifecycle and replacement decision record — Decision page for choosing repair, used board, refurbished drive or replacement when a legacy SJ300/L300P asset has a costly fault.

Open →
Danfoss VLT 2800 / VLT 2900
Danfoss VLT 2800 CB1-CB3 Control-Board Drawing Family

Reviewed control-board drawing set for VLT 2800 logic, display, input and low-voltage references — The VLT 2800 CB1-CB3 drawing set exposes +5 V, +24 V, VREF and keypad/display-related logic paths useful when the drive has a blinking display, partial display, I/O reference problem or control-card suspicion.

Open →
Danfoss VLT 2800 / VLT 2900
Danfoss VLT 2900 DB1-DB4 Power and Gate-Driver Drawing Family

Reviewed power / driver drawing set for VLT 2900 gate-drive and auxiliary-supply diagnostics — The VLT 2900 DB1-DB4 drawing set shows DC input references, auxiliary rail generation, optically isolated or buffered signal paths and six-channel gate-driver relationships relevant to overcurrent, internal short and post-repair pre-power checks.

Open →
VACON NXL
VACON NXL DB1-DB4 Power-Board Drawing Family

Reviewed power-board drawing set for discontinued VACON NXL drives — The VACON NXL DB1-DB4 drawing set exposes auxiliary supply, gate-driver, CT/reference and LM339 comparator-style protection relationships that support no-display, overcurrent and earth-fault triage on an inactive drive family.

Open →
PowerFlex 400
PowerFlex 400 110 kW Drawing Family

Reviewed four-sheet power/control drawing set for a large-frame PowerFlex 400 reference — A model-family record for the reviewed POWERFLEX400-110KW DB1 through DB4 drawing set. The set supports evidence mapping around charge circuitry, DC-bus references, auxiliary supply feedback and large-frame repair decisions, but exact catalogue and revision match must be verified before board replacement.

Open →
PowerFlex 400
PowerFlex 400 Fan and Pump Drive Family

PowerFlex 400 application family for fan and pump service — PowerFlex 400 is positioned around fan and pump applications, where overvoltage, undervoltage, ground fault and power-loss events often require separation of installation, load inertia, line condition and internal drive evidence.

Open →
PowerFlex 400
PowerFlex Component-Class DSI Communication Context

Communication and adapter context for PowerFlex 4/40/400 class drives — A communication-family record for F081/Comm Loss events where RS-485/DSI wiring, adapter state, parameter timing and PLC recovery behavior must be separated before replacing a drive or communication module.

Open →
Altivar 71 / ATV71
Schneider Altivar 71 Drive Family

Discontinued constant-torque AC drive family with official documentation and active repair/replacement demand — ATV71 is a broad Altivar family covering synchronous and asynchronous motor applications. This record orients technicians around official SCF, USF and control-power evidence rather than treating every fault as a board replacement.

Open →
Altivar 71 / ATV71
ATV61 / ATV71 Power Board and Spare-Parts Decision Family

Power-board repair and replacement decision record for ATV61/ATV71 frames — Schneider public FAQs show that ATV71 power-board replacement can be a Field-Services-only or repair-versus-replace decision, creating a high-value need for evidence before parts sourcing.

Open →
Altivar 71 / ATV71
ATV61 / ATV71 Control Board and HMI Power Family

Control-board, HMI and external 24 Vdc support context — Schneider guidance confirms an external 24 Vdc supply can power the control board and HMI for information retrieval, supporting a practical route for blank-display and dead-control investigations.

Open →
UE Frame 4 / Frame 5-7 Power-Board Families
PDL UE Frame 4 Power-Board Drawing Family

Frame 4 VSD power and protection drawing set / E141-611P reference — Model-family record for UE Frame 4 drawings DB1 through DB5. The set identifies PDL ELECTRONICS LTD, E141-611P, +BUS/-BUS regions, UC3833 and TL431 supply evidence, 3842 switching-supply evidence, LM339 comparator/protection paths, and U/V/W phase IGBT references.

Open →
UE Frame 4 / Frame 5-7 Power-Board Families
PDL UE Frame 5 / 6 / 7 Power-Board Drawing Family

Higher-frame VSD power-stage and auxiliary-supply drawing set — Frame 5/6/7 records extend the same PDL UE evidence pattern to larger frames using DB1-DB3 sheets. Visible references include +BUS/-BUS, IGBT100, IGBT200, UC3833, 3842, TL431 and comparator/protection regions.

Open →
UE Frame 4 / Frame 5-7 Power-Board Families
PDL Elite / Microdrive Legacy Support Context

Public manual and upgrade context for legacy PDL drives — A context record linking the reviewed UE Frame power-board evidence with public PDL Electronics manuals, legacy service-agent statements and replacement/upgrade pathways for obsolete PDL drives.

Open →
EV1000 / EV2000 Control-Board Faults
Emerson EV2000 Control Board

Legacy EV2000 VFD control board / logic and current-detection repair reference — Model-family record for EV2000 boards where POFF, no-display, E004, E010, E019 and run-command failures require separation of DSP/CPLD logic, 5 V / 3.3 V supplies, analog reference, current-detection ICs and post-repair gate-drive risk.

Open →
EV1000 / EV2000 Control-Board Faults
EV1000 Small Control Board 03025856

Small-frame EV1000 control board no-display / SPI-DSP diagnostic reference — Control-board record for EV1000 small board 03025856, where repair notes connect no-display behavior to CN3 SPI signal evidence, U4 linkage, DSP-side signal state and low-voltage logic conditions.

Open →
EV1000 / EV2000 Control-Board Faults
EV1000 / EV2000 Current Detection Path

Hall sensor / current detection amplifier fault family — Family record for E019-style current-detection faults, separating Hall sensor, phase-current signal, amplifier IC, IC power and control-board connector evidence.

Open →
Series 15H Inverter Control
Baldor Series 15H Inverter Control

Legacy PWM inverter drive family with reviewed auxiliary-power drawing reference — A Series 15H family record linking official fault language with a power-supply schematic labelled BALDOR 15H. The schematic is useful for controlled board-level reasoning, but is not asserted as applicable to every 15H frame or catalogue number until a board identifier and drive nameplate are matched.

Open →
EDS1000
ENC EDS1000-2S0015

1.5 kW / single-phase 220 V input general-purpose inverter circuit reference — A discontinued ENC / Shenzhen Encom EDS1000 model for which the project has a two-sheet circuit map covering the DC-link power stage, isolated gate-drive supply, fan and relay control, switching-supply feedback, and isolated current-feedback interface.

Open →
Starvert iS5
LG / LS SV185iS5-4N0

Starvert iS5 400 V-class 18.5 kW / 25 HP drive repair reference — A discontinued LG/LS Starvert iS5 model with documented board-level repair evidence: failed IGBT and CPU board, repeat CPU-board destruction after repair, and a control-power supply whose 24 V output rose as high as approximately 56 V before feedback-path repair.

Open →
FR-A740
Mitsubishi FR-A740 7.5 / 15 / 37 kW Drawing Family

Reviewed power-driver drawing reference set — A matched drawing family covering three 400 V FR-A740 power sizes. The 37 kW sheets expose auxiliary SMPS rails, isolated gate-driver channels, fan command circuitry, thermal signals and connector relationships suitable for structured diagnostic mapping.

Open →
A1000
Yaskawa A1000 22 kW DB1–DB5 Drawing Family

Reviewed five-sheet board/circuit reference — Five circuit sheets establish the 22 kW reference path from auxiliary power conversion and isolated gate rails to voltage/current feedback, fan/relay signalling and output-stage protection evidence.

Open →
ACS800
ABB ACS800-01 / ACS800-04 / ACS800-07

ACS800 single drive and drive-module reference — A practical family record covering wall-mounted, module and cabinet ACS800 arrangements used as the entry point for PPCC LINK and inverter short-circuit investigation.

Open →
DCS800
ABB DCS800 D1–D7 Converter Modules

DC drive converter platform — DCS800 converter modules span D1 through D7 frames and use different power-interface arrangements while retaining a diagnostic relationship between control electronics, auxiliary supply, measurement/firing interfaces and the field system.

Open →
ALPHA6000S / ALPHA6000V / ALPHA6700S
ALPHA6000S

General-purpose VFD — ALPHA6000S is a general-purpose drive family offering V/f control, sensorless vector control and separated V/f operation for industrial motor-speed applications.

Open →
ALPHA6000S / ALPHA6000V / ALPHA6700S
ALPHA6000V

Vector-control VFD — ALPHA6000V extends the family with sensor-feedback closed-loop vector control in addition to V/f, sensorless vector and separated V/f operating modes.

Open →
TD900
TD900-4T0015G

AC drive diagnostic model reference — This model record starts with a documented IGBT turn-off path observation: its drive stage uses an HCPL-3120-type driver arrangement with a diode/resistor/capacitor network important to gate discharge behavior.

Open →
616G3
Yaskawa 616G3 55 kW

Large-power VFD repair reference — A main-circuit reference for a 55 kW drive with three-phase rectification, DC-link capacitor bank, six IGBT arms and dedicated parallel protection/suppression elements across the switching devices.

Open →
MICROMASTER 430 / 440 Service Track
MICROMASTER 430

Fan and pump variable frequency drive — The MICROMASTER 430 range controls three-phase AC motor speed in 7.5 kW to 250 kW applications, with strong emphasis on fan and pump operation.

Open →
SIMOVERT MASTERDRIVES 6SE70 / 6SE71
Siemens 6SE70 / 6SE71 Vector Control Platform

SIMOVERT MASTERDRIVES Vector Control device and cabinet system family — Platform reference distinguishing standalone 6SE70 units from integrated 6SE71 cabinet systems, and mapping converter, inverter, rectifier/regenerative and common-DC-bus configurations to diagnostic work.

Open →
SIMOVERT MASTERDRIVES 6SE70 / 6SE71
Siemens 6SE7021 / 6SE7022 / 6SE7023 Circuit Drawing Family

Power and driver circuit mapping record — Editorial circuit-map entry based on identified 6SE7021, 6SE7022 and 6SE7023 schematic sets, used to organize auxiliary supply, DC-link, IGBT-drive and status/protection signal investigations without distributing original drawings.

Open →